CW3E id: FMI
CDEC id: FMI
NWS id: --
Lat/Long: 37.773700 / -119.861900
Elevation: 1720m
Team Lead: [private]
Install Date: June 25, 2008
Permit Expires: Dec. 31, 2024
Watershed: Tuolumne
Telemetry: Cell
Monument: Pole
Land Owners: NPS
Permit Type: NPS
Site Type: SurfaceMet+Soil

HCN Site 043

DL4 Smoil site mounted on an aluminum pole. Located along Highway 120 about 50 meters up a hill in the forest on the South/West side of the road. Site burned during the 2013 Rim Fire.


Site Photo:



Sensors

TypeLabelModelSNInstalled OnLatest Calibration
Air Temperature/Relative Humidity --Sensirion SHT-85 N/A 43 June 20, 2024 None
Barometer --Intersema MS5534C N/A 43 June 25, 2008 June 20, 2024
Fuel Moisture + Temp --Campbell Scientific CS506-L N/A 43 June 25, 2008 None
Pyranometer --LICOR LI-200R 100385 July 30, 2023 July 26, 2023
Soil Moisture Soil0 (10 cm)Decagon 5TE N/A 43 0 Oct. 1, 2013 None
Soil Moisture Soil1 (30 cm)Decagon 5TE N/A 43 1 Oct. 1, 2013 None
Soil Moisture Soil2 (60 cm)Decagon 5TE N/A 43 2 Oct. 1, 2013 None
Soil Moisture Soil3 (90 cm)Decagon 5TE N/A 43 3 Oct. 1, 2013 None
Tipping Bucket --Texas Electronics TE525USW 8 in. funnel 73679-817 June 20, 2024 June 1, 2024


Other Equipment

TypeLabelModelSNInstalled On
Data LoggerNoneDL4-GP101June 2, 2021
Data LoggerNoneIO1-Met9Oct. 1, 2013
Data LoggerNoneIO3-GPS/COMM24Oct. 1, 2013
Solar PanelNone5WNoneOct. 1, 2013
Solar PanelCell Telemetry Solar PanelNewpowa 5WNoneFeb. 11, 2024
BatteryCell Telemetry BatteryPowerSonic PS-12140F2NoneFeb. 11, 2024
BatteryDatalogger BatteryPowerSonic PSH-1255F2NoneJune 20, 2024
Cell ModemHCN - FMIRV50LT91860149021036Aug. 26, 2025


Funding Sources

None