Summary

Station Maintenance

Details

Personnel: Douglas Alden and Sam Babbitt

On Arrival:
Visual Inspection:
Tipping bucket is clear.
Need to purchase bird spikes to put around top of pole and crossarm.

Battery Voltage: 13.78
Current: 3.5/1.3/1.1

Clock +01:45

soil0 not functional
soil1 only provides intermittent temperature

Barometer Offset not checked. Paros is not functional.

Old Sensors
Pyranometer: PY112764 -14.33 10-Sep-2021
Anemometer: 55010
Tipping Bucket: 40273-906 dec 2021
SD: 110

New Sensors
Pyranometer: PY58241 -10.74 30-OCT-2023
Anemometer: 24097
Tipping Bucket: 40273-906 DEC-2021 with bird spikes
SD: 039
Installed new SHT85 humidity sensor

Upgraded firmware to v2.0.3 Mt. Ranier

Unplugged soil0 and soil1 from IO3-GPS/Comm

Logger set to transmit every 30 minutes at minute offset 4.

Downloaded memory card and processed data.

Replaced enclosure.

After start:
Battery Voltage: 13.83
Current: 3.0/1.3/1.2

Sensor Heights:
T/RH 114.5"
Anemometer 172.5"
Solar 159"
Barometer 130"
Tipping Bucket 129.5"