CW3E id: WHT
CDEC id: WIC
NWS id: --
Lat/Long: 39.278090 / -123.110880
Elevation: 275m
Team Lead: John Deane
Install Date: Aug. 27, 2017
Permit Expires: --
Watershed: Russian
Telemetry: Cell
Monument: Pole
Land Owners: private
Permit Type: Handshake
Site Type: Stream

White Creek flows through the Magruder Ranch. The stream gage is located on the south bank of the creek, against a rock outcropping along with the staff plate. The staff plate and stilling well are surrounded by dense poison oak. Use caution when working on the stilling well or staff plate. A trail cam is strapped to the oak tree on the bank opposite the stream gage.

Maximum Wadeable Level: 1.2 ft on pressure transducer doable on 3/5/2024

Figure 1.  Staff plate, stilling well, and data logger at WHT

Figure 2. Photo of the tree on the bank opposite of the stilling well and staff plate where the trail cam is installed



Tasks

None

Sensors

TypeLabelModelSNInstalled On
Pressure transducer--ONSET MX2001-04-SS-S21919757April 19, 2023
Trail Camera--Spypoint Flex-S2J322I0144June 25, 2024


Other Equipment

TypeLabelModelSNInstalled On
Data LoggerNoneHOBO RX2100 Station - CELL-4G22050044June 24, 2024
Staff gageNone-----------NoneAug. 27, 2017


Visits

OnSummary
Feb. 6, 2025High water msmt
Dec. 16, 2024Manual Discharge Measurement
Dec. 4, 2024Power Cycled Trail Camera / Downloaded photos
July 29, 2024Data Downloads/Maintenance/Reference Level Check
June 25, 2024Manual Discharge Measurement/Replaced Trail Cam and HOBOlink Datalogger
March 5, 2024Manual Discharge Measurement/Reference Level Check
March 4, 2024Data Downloads/Maintenance
Nov. 16, 2023Reference Level Updated
Oct. 9, 2023Data Downloads/Installed HOBOlink Telemetry/Installed new Trail Cam w/ Cell-link
April 19, 2023Manual Discharge Measurement/HOBOlink Telemetry Installed/Demobed Trail Cam and Solinst loggers/Reference Level Check/Changed units on solinst logger
June 1, 2022Data Download / Manual Discharge Measurement
Jan. 30, 2022Stream Survey/Installed Barologger/Manual Discharge Measurement
Jan. 26, 2022Manual Discharge Measurement/Downloaded Data/Installed Trail Cam
Nov. 10, 2017Staff Plate and Camera Installed
Sept. 22, 2017Stream Survey Conducted
Aug. 27, 2017Stream Gage Installed


Funding Sources

StartEndSource
Aug. 27, 2017 -- USACE FIRO