System offline likely due to tripped breakerDetails
System has been offline for several days likely due to tripped breaker. Megan and Andrew have been contacted to reset the 20A breaker in the shed labeled Wood Shed if it has tripped.
Interestingly, the data from the CR1000 continued to be transmitted for several days after the LiDAR/Disdro. All that is need for the CR1000 is for the RF407 and the RV55 to have power. The computer system is monitoring the UPS and will shutdown when the UPS battery reaches a given remaining capacity. Even after the computer shuts down, the RF407 and RV55 will continue to get power from the UPS until the UPS triggers a power shutdown. Based on data timestamps the computer shutdown approximately 2 days 6 hours before the RF407 and RV55.
Last timestamps:
CR1000 CHZ_Status.dat: 2025-02-07 01:00:07.95
LiDAR: 2025-02-04 19:00
Disdro: 2025-02-04 18:59:57