CDEC id: DPP
NWS id: --
Lat/Long: 37.629300 / -119.084700
Elevation: 2303m
Team Lead: Hart Wanetick
Install Date: Aug. 31, 2024
Permit Expires: --
Watershed: San Joaquin
Telemetry: Cell
Monument: Tower
Land Owners: NPS
Site Type: SurfaceMet+Soil
SurfaceMet
HCN Site 033
DL4 Smoil installation mounted on a Rohn 45G tower in Soda Springs Meadow. Tower is shared with DWR. Soil is Alluvial fill and site may flood in spring due to high water events on the middle fork of the San Joaquin River.
SurfaceMet Site Photo:
Stream Gage
A Solinst Levelogger stream gage is installed in the middle fork of the San Joaquin River near the site of the old pump house. The Levelogger is housed in a concrete anchor located in the river. A wire rope runs from the anchor back to a tree. The sensor is connected to a data cable that runs back to the side of the river and up through conduit attached to a tree.
Stream gage site looking downstream. Sensor is cabled to left riverbank (
video description
)
Tasks
NoneSensors
Type | Label | Model | SN | Installed On |
---|---|---|---|---|
Air Temperature/Relative Humidity | -- | Sensirion SHT-85 | N/A 32 | June 23, 2024 |
Barometer | -- | Intersema MS5534C | N/A 32 | June 21, 2007 |
Fuel Moisture + Temp | -- | Campbell Scientific CS506-L | N/A 32 | Aug. 7, 2010 |
Pyranometer | -- | LICOR LI-200 | 60317 | Aug. 3, 2023 |
Soil Moisture | Soil0 (10 cm) | Decagon ECH20-TE | N/A 32 0 | June 22, 2008 |
Soil Moisture | Soil1 (50 cm) | Decagon ECH20-TE | N/A 32 1 | June 22, 2008 |
Tipping Bucket | TB0 (Heated) | Texas Electronics TE525USW-HT 8 in. funnel w/ Heater | 40279-906 | Aug. 3, 2023 |
Tipping Bucket | TB1 (Unheated) | Texas Electronics TE525USW 8 in. funnel | 41312-609 | Aug. 3, 2023 |
Other Equipment
Type | Label | Model | SN | Installed On |
---|---|---|---|---|
Cell Modem | None | Digi Transport LR54 | LR001552 | July 1, 2017 |
Visits
On | Summary |
---|---|
Jan. 27, 2025 | SurfaceMet real-time feed offline |