Summary
Sensor replacement and firmware upgradeDetails
Personnel: Douglas Alden, Ross Beaudette
Clock OK +00:00:30
On arrival:
Battery Voltage: 13.9V
Current: 4.3/2.1/1.9 mA
Upgraded firmware to v2.0.3 Mt. Rainier
Old SD: 115
New SD: 094
Replaced tipping bucket
Old Tipping Bucket: 43923-510 Aug 2023
New Tipping Bucket: 41472-609 Sept 2024
Replaced SHT75 humidity sensor with SHT85.
Wind speed is not working. Processed data shows off and on issues with wind
speed going back to October 2024.
After startup:
Battery Voltage: 13.9
Current: 3.1/1.9/1.6